Function Introduction:
This online/offline comprehensive controller has 20 pulse valve control ports and 5 lift valve control ports, and it also supports RS485 fieldbus (Modbus RTU protocol) for remote control
Supports AC220V (± 10%) 50HZ or DC24V (± 10%) power supply;
Supports up to 20pcs of DC24V pulse valves;
Supports up to 5pcs of DC24V lift valves;
The maximum output power of the whole equipment is DC24V @ 1.5A;
The control instrument can be configured with online and offline cleaning modes, and the offline mode supports lifting valves;
The control instrument can be configured with a cleaning trigger mode that includes timing execution and pressure differential activation of dry contacts;
RS485 interface supporting Modbus RTU protocol;
Supports on-site jog control for on-site debugging
Technical parameters and indicators:
Input power supply voltage:AC220V(±10%)50HZ or DC24V(±10%);
Output voltage:DC24V;
Output current:1.5A;
Compartment: Number of lift valve,range【0-5,Default value 0】,Skip the parameters related to the lift valve when the value is 0;
Waiting: Lift valve waiting time, range [0-60 seconds, unit 1 second, default value 8 seconds]
Sedimentation: The settling time of the lift valve ranges from 0 seconds to 60 seconds, with a unit of 1 second and a default value of 8 seconds;
Interval: Lift valve interval time, range [0 seconds to 999 seconds, unit 1 second, default value 10 seconds]
Pulse valve: Number of pulse valves, range [1-20, default value 20]. When there is no lift valve, it is the total number of pulse valves. When there is a lift valve, it is the number of pulse valves in a single chamber
Pulse width: Pulse valve opening time, range [10 milliseconds -9999 milliseconds, unit 1 millisecond, default value 80 milliseconds]
Interval: Pulse valve interval time, range [1-600 seconds, unit 1 second, default value 1 second]
Cycle: Cycle time, range [0 minutes to 9999 minutes, unit 1 minute, default value 0 minutes]
Definition of Function Code:
F1: control mode, range [timing/pressure differential, default timing]
F2: Electronic fuel injection blowing delay, range [0 seconds -300 seconds, unit 1 second, default value 10 seconds]
F3: Modbus address, range [1-127, default value 1]
F4: Modbus baud rate, such as 96 is 9600, range [48009600192003840057600115200, default value 9600]
Model specifications and shell installation dimensions:
Model | Number of pulse valve controlled | Shell material | Main shell size(mm)H *W *L |
SXC-SK-205L | 1-20 | PC | 190*255*105 |