Product Introduction:
The SXC-6 differential pressure controller is specifically designed for dust collectors with requirements for inlet and outlet differential pressure. Using an intelligent digital display controller, the pressure differential sensor is integrated to control the controller through alarm parameters.
Data Setting of SXC-6 Differential Pressure Controller:
The SXC-6 differential pressure controller has set low alarm 1 to 1.00KPa, high alarm 2 to 1.40KPa, and low low alarm 3 to 1.00KPa before leaving the factory. Our company only provides high alarm wiring terminals for the SXC-6 differential pressure control instrument. If users require low alarm 1 or low alarm 3 signals, the company can provide wiring terminals for the SXC-6 differential pressure control instrument. If users need to modify data during use, please follow the steps below:
Press the SET button, and the digital display tube 2 will show ALAR, indicating that it can be operated;
Press the SET key to display an alarm of 1:1.00KPa, and use the ▲ or ▼ keys to modify the data;
Press the SET key to display alarm 2: 1.40KPa, press the ▲ or ▼ keys to modify the data;
Press the SET key to display an alarm of 3:1.00KPa, and use the ▲ or ▼ keys to modify the data;
Press the SET key, display END, indicating successful modification;
Press the SET key to return to working mode.